CONTACT US      email    |   07 3823 1922 

OPTIFLUX 3070 Electromagnetic Flow Meter

krohne OPTIFLUX 6050 MAGMETERElectromagnetic flowmeter for basic hygienic applications

The Krohne OPTIFLUX 6050 is an electromagnetic flowmeter (EMF) designed and used for basic hygienic applications in the food sector. Offering cost-effective flow measurements where extremely high accuracy, extensive diagnostics, or a wide range of digital communication options are not a priority.

This 3A and EHEDG-certified flowmeter comes with industry-specific hygienic adapters. It has no crevices, gaps, or blind spots and has been specifically designed to stay free of contamination. This way, it complies with the most stringent hygienic demands in the food and beverage industry.

Due to its reinforced liner, the flowmeter also withstands high process temperatures (up to 140°C / 284°F) and vacuum impacts. The EMF can be used in CIP or SIP cleaning procedures. In addition to weld-end connections, the OPTIFLUX 6050 is available with a large number of hygienic fittings, including DIN 11851, DIN 11864, clamp, and SMS. A full on-site verification of the flowmeter without process interruption can be carried out using the OPTICHECK service tool.

Features of the Krohne OPTIFLUX 6050 magmeter

  • Bi-directional flow measurement over a wide dynamic range
  • Designed for conductive liquids ≥5 μS/cm (water ≥20 μS/cm)
  • Suitable for solid content up to 10%, e.g. yogurt with fruit pieces, soups with vegetable pieces, etc.
  • Compact version or a remote version with wall-mount housing (with or without display)
  • PFA liner reinforced with embedded stainless steel grid for vacuum resistance
  • Unique L-shaped gasket prevents expansion of gasket for increased lifetime
  • Complies with FDA and EC1935/2004 regulations
  • Wide range of electrode materials
  • Available with industry-specific installation lengths and various hygienic process connections
  • Full bore design: No moving parts, no wear, no pressure loss
  • On-site verification of flowmeter with OPTICHECK service tool

Suitable applications for the WATERFLUX 3070

General
  • Simple hygienic applications
  • For large-scale production plants with diameters up to DN150 / 6"

Food and beverage industry

  • Beverages (soft drinks, beer, wine, fruit juices, etc.)
  • Milk and other dairy products
  • CIP media (incl. acids and caustic solutions)

Pharmaceutical industry

  • Processing of drugs, caustic sodas, acids, proteins, antibiotics

Optiflux 3070 Specifications

 Nominal Diameter  DN2.5 ... 150 / 1 / 10" ... 6"
 Measuring Range
 -12 .... +12m/s / -40 .... +40 ft/s
 Repeatability  +0.1% of MV, minimum 1mm/s
 Long term stability  +0.1% of MV 
 Process Temperature
 Separate flow sensor: -40 to +140°c
 Compact with IFC 300 converter: -40 to +140°c 
 Compact with IFT 050 and IFC 100 converter: -40 to +120°c [at ambient temperature ≤40°c 
 For ISO 2852 and Tri-clamp versions: -40 to +120°c 
 Ambient Temperature
 -40 to +65°c
 IFC 100 stainless steel version:  -40 to +60°c 
 Storage Temperature
 -50 to +70°c
 Pressure
 Ambient Pressure: Atmospheric
 Vacuum Load: 0 mbar / 0 psi

Download PDF information on the Krohne OPTIFLUX 6050 Hygenic Electromagnetic Flow Meter

DOWNLOAD DATA SHEET

  • Flow Type: Liquid Flow Meters, Low Flow